ANALYSIS THE EFFICIENCY OF BOILER 2011 UA WATER TUBE TYPE AT PT PERTAMINA RU III (PERSERO) PLAJU

Authors

  • Dian Dwi Lestari Atma Jaya Catholic University of Indonesia
  • Isdaryanto Iskandar Atma Jaya Catholic University of Indonesia
  • Wendi Akamigas Palembang of Polytechnic, Indonesia

DOI:

https://doi.org/10.53625/ijss.v2i4.4164

Keywords:

Efficiency Boiler Steam Direct Method Enthalpy

Abstract

One of the most important tools in steam production in the oil and gas industry is a boiler. Along with the increasing demand for steam, it is necessary to think about ways to increase the efficiency of the boiler. A boiler or steam boiler is a closed vessel-shaped device used to produce steam or steam. Boilers are designed to transfer heat from a combustion source. With Used the direct method (Direct Method) to calculate boiler efficiency. The pressure and temperature data of the feed water and steam is processed through the data interpolation process to obtain the enthalpy value of the feed water and steam enthalpy. Based on the calculation results obtained boiler efficiency results of 78.11%, 78.27%, and 79.75% with an average efficiency of 78.71%, and from the results of boiler efficiency calculations from the report of PT Pertamina RU III (Persero) obtained results of 89,75% in 1991. The efficiency of the above boiler has decreased by 11.04%. The decrease was caused by several factors, namely shells, valves, and instrumentation that had been eaten by age and damaged tubes.

References

Adli, Zul, et al. 2018. Performance Analysis of the Takuma N-600 SA Boiler with a Steam Level of 20 Kg/cm2/259OC Fueled by Computation-Based Fiber and Palm Oil Shells. Aceh: Lhokseumawe State Polytechnic.

Kharisma, Aji Abdillah, and Arif Budiman.

2020. Calculation of the Efficiency of Fire-Tube Boiler Machines Using the Direct and Indirect Methods for Granular Pellet Products. West Jakarta: Gunadarma University. Muin A, Syamsir. 1998. Energy Conversion I (Steam Kettle). Jakarta : Rajawali Press Publisher.. Perry, KH, and Clinton, CH, “Chemical Engineering's Hand Book,” 1989, 6thedition, Mc Graw Hill Kogakusha ltd, Tokyo

Purba, Jhonas. 2015. Design of a Fire Pipe Boiler for Boiling Soybean Porridge in the Tofu Industry with a Saturated Steam Capacity of

160 kg/hour. Riau University of Pasir

Pengaraian

Raharjo, WD, and Karnowo. 2008. Energy Conversion Machine. Semarang : Semarang State University.

Renata, Leny EP 2013. Unit 3 Condenser Efficiency. Palembang : State Polytechnic of Sriwijaya Palembang.

Sugihartono, A. 2020. Calculation of Boiler Efficiency by Direct Method in Fire Pipe Boilers. Blora: PPSDM MIGAS Cepu.

User's Manual, “Preelementary Offsite & Utilities Operating Manual'MW Kellog Plant Service. October. 1984

Downloads

Published

2022-12-03

How to Cite

Lestari, D. D., Iskandar, I., & Wendi, W. (2022). ANALYSIS THE EFFICIENCY OF BOILER 2011 UA WATER TUBE TYPE AT PT PERTAMINA RU III (PERSERO) PLAJU. International Journal of Social Science, 2(4), 1865–1872. https://doi.org/10.53625/ijss.v2i4.4164

Issue

Section

Articles