OPTIMASI PENGGUNAAN FAKTOR EKSPOSI PADA PEMERIKSAAN BLASS NIER OVERZICHT (BNO) PADA PASIEN DENGAN BERAT BADAN 60-70KG
Keywords:
Radiography, Abdomen, Exposure Factors, Body Weight, Image QualityAbstract
Background: The abdomen is a body part frequently examined through radiography to diagnose conditions such as acute abdomen, meteorism, or ileus. Proper exposure factor settings, particularly for patients weighing 60–70 kg, are crucial for obtaining high-quality diagnostic images while minimizing radiation doses. This study aims to analyze the optimization of exposure factor usage in abdominal radiography for patients weighing 60–70 kg at Sunan Kudus Islamic Hospital. Method: This research employed a descriptive qualitative method with a case study approach. Data collection was conducted in May 2025 at the Radiology Installation of Sunan Kudus Islamic Hospital. The sample consisted of three patients undergoing abdominal examinations. Data were gathered through observations, interviews with one radiology specialist and three radiographers, as well as documentation of projections. Data were analyzed through reduction and narrative presentation based on theoretical references for conclusions. Result: The examinations were performed with AP Supine, semi-sitting, and Left Lateral Decubitus (LLD) projections using exposure settings of 75–80 kV and 20–25 mAs. The resulting images displayed clear anatomical structures such as lumbar vertebrae, pelvic collar, and both large and small intestines, without significant noise. The radiographs were able to detect conditions such as obstructive ileus, pneumoperitoneum, and meteorism with localized ileus in the mid-abdomen. All patients received high- quality images without the risk of excessive radiation. Conclusion: The exposure settings of 75–80 kV and 20–25 mAs are effective for patients weighing 60-70kg. It is recommended to establish specific Standard Operating Procedures (SOP) regarding exposure factors for patients within this weight range at the Radiology Installation of Sunan Kudus Islamic Hospital
References
Afdali, M., DAUD, M., & PUTRI, R. (2018). Perancangan Alat Ukur Digital untuk Tinggi dan Berat Badan dengan Output Suara berbasis Arduino UNO. ELKOMIKA: Jurnal Teknik Energi Elektrik, Teknik Telekomunikasi, & Teknik Elektronika, 5(1), 106. https://doi.org/10.26760/elkomika.v5i1.106
Asriningrum, S., Ansory, K., & Hasan, P. T. (2021). Faktor Eksposi terhadap Kualitas Citra Radiografi dan Dosis Pasien Menggunakan Parameter Penilaian Signal to Noise Ratio (SNR) pada Pemeriksaan Thorax Posteroanterior dengan Menggunakan Pesawat Computed Radiografi. Jurnal Imejing Diagnostik (JImeD), 7(1), 15–18. https://doi.org/10.31983/jimed.v7i1.6650
Handayani, s. 2021. (2019). Anatomi dan fisiologi tubuh manusia. Jawa Barat: CV Medika Sains Indonesia. In Sustainability (Switzerland) (Vol. 11, Nomor 1).
Lampignano & Kendrick, 2018. (2018). Textbook of Positioning and Related AnatomyNo Title.
Mareta, S., Puspita, O. S., & Yunika, L. (2023). Perbandingan Gambaran Radiograf Abdomen Proyeksi Left Lateral Decubitus (LLD) Dengan Variasi Waktu 5, 10, dan 20 Menit Untuk Memperlihatkan Udara Bebas. 4(4), 6267–6273.
Rosidah, S., Soewondo, A., & Adi, M. S. (2020). Optimasi Kualitas Citra Radiografi Abdomen Berdasarkan Body Mass Index dan Tegangan Tabung pada Computed Radiography. Jurnal Epidemiologi Kesehatan Komunitas, 5(1), 23–31. https://doi.org/10.14710/jekk.v5i1.5866
Sparzinanda, E., Nehru, N., & Nurhidayah, N. (2018). Pengaruh Faktor Eksposi Terhadap Kualitas Citra Radiografi. Journal Online of Physics, 3(1), 14–22. https://doi.org/10.22437/jop.v3i1.4428
Tortora G. J., & D. B. (n.d.). principles of anatomy and physiology. john wiley & sons.
Wulan Safitri, R., Sudarsih, K., & Andriani, I. (2018). Teknik Pemeriksaanradiografi Abdomen Akut Dengan Kasus Pneumoperitoneum Di Instalasi Radiologi Rsud K.R.T Setjonegoro Wonosobo. Jurnal Ilmiah Radiologi, 3(2).